SKU
HI84533-55

Pump Calibration Standard for Formol Number Mini Titrator HI84533-55

€33.00
In stock
The HI84533-55 is a 120 mL bottle of pump calibration solution that is used to calibrate the dosing system of the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis. A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84533 in determining the exact amount of total assimilable nitrogen. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.
  • Pre-measured solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

Details

The HI84533-55 is a 120 mL bottle of pump calibration standard solution that is used for both low and high range determination of formol number. Formol number of wine and fruit juice, as performed on the HI84533 mini titrator, utilizes a simple sample preparation, a high quality titrant dosing pump, potentiometric endpoint detector, and automatic computations. To maintain the high precision of the titrator, a simple pump calibration procedure is required. To achieve precise results, the instrument occasionally requires a pump recalibration. The pump calibration involves the analysis of a known volume of a known solution and compensates for changes in pump dosing that may occur due to many factors including tube stretching or aging. This procedure should be performed regularly with the HI84533-55 pump calibration solution to accurately determine the formol number of wines and fruit juices.