Modular Multiparameter pH/ORP/ISE/EC/DO Instrument - HI6000 Series
The HI6000 modular multiparameter instrument is designed for laboratories, industries, and educational institutions that require precise and customizable measurements. Thanks to its modular platform, up to three modules can be installed simultaneously, including pH/ORP, pH/ORP/ISE, Dissolved Oxygen, and Conductivity, ensuring maximum reliability. With its intuitive touchscreen interface, context-sensitive help menu, and video tutorials, the HI6000 simplifies daily operations and optimizes workflows, making it an essential tool for any research environment.
- Fully configurable
- Versatile connectivity
- State-of-the-art technology
Watch the video
And discover all the features of the HI6000
- Modularity
- Advanced measurement and calibration functions for pH, ISE, EC, and DO
- Easy data sharing via Wi-Fi, Ethernet, USB
- Connectivity with magnetic stirrers, printers, keyboards, barcode scanners
- Optimal user experience
- and much more.
Go Modular
Hanna Instruments offers four measurement modules for pH/ORP, pH/ORP/ISE, Dissolved Oxygen (DO), and Conductivity (EC). With a compact, space-saving design, you can easily install and exchange up to three modules, providing total flexibility in measurements. Any combination of 1, 2, or 3 modules can be used, making your laboratory ready for future projects.
Advanced customization of display settings, user accounts, and application-specific profiles enables fast and direct measurements without the need to modify settings.




Accurate and Reliable
In combination with appropriate electrodes, the HI6000 meter ensures extremely accurate and reliable measurements for all laboratories. It is possible to view up to three measurement channels simultaneously, customizing the display settings. Data can be shown in a simple or detailed format, in either tabular or graphical form.
Precision
The HI6000 series allows calibration up to 5 points for pH, ISE, and Conductivity, ensuring optimal results.
The HI6000 automatically identifies the buffer closest to the measured pH value, selecting from all available buffers within the buffer group.
Go Digital
Data Logging
The HI6000 series simplifies data management, eliminating the risk of errors caused by manual transcription. With the capacity to store up to 1,000,000 data points per user, it offers extraordinary flexibility in sharing results.
Connectivity and Services
Data can be easily transferred via Wi-Fi, Ethernet, email, web server, USB flash drive, or directly to a PC, without the need for additional software. The integrated Wi-Fi connection enables fast and wireless sharing, improving operational efficiency. Additionally, you can connect accessories such as a keyboard, printer, stirrers, and barcode scanners to further optimize workflow.

Simplicity Without Compromise
Simple and Intuitive Interface
The HI6000 Series is designed to provide intuitive control and unparalleled ease of use. The instrument features a large capacitive touchscreen with multi-touch support, enabling smooth interaction.
Built-in Help and Video Tutorials
A help menu provides an overview of the main features through text and video tutorials, ensuring quick assistance. User-friendly icons and symbols make navigation and interpretation of the instrument's functions easy.
"Additionally, the system offers five different display modes: Standard, Simple GLP with calibration information, Full GLP with details on electrode status and calibration points, Interactive Graph, updated in real time, Tabulated Data with date, time, and notes.
Certified Precision
Certifications
Hanna Instruments supports you by offering certified products and periodic calibration services. All instruments and probes come with a Certificate of Quality, and our technical department is available to provide factory calibration renewal or annual calibration with certified standards.
Support
Our technical team is available to offer you support through:
- Telephone assistance
- Quick interventions
- Consultations to help choose the most suitable electrodes for your needs
- Repairs at our facility
Specifications
Characteristic |
Details | |
Reading | Stability criterion | Accurate; Medium; Fast |
Sampling rate | 1000 ms | |
Data recording |
Typology |
Automatic; Manual; Autohold |
Number of registrations |
Max 50,000 per file, Store up to 1,000,000 data per user |
|
Automatic range |
1, 2, 5, 10, 30 seconds; 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
|
Sample ID |
Incremental or Manual mode |
|
Export |
File format .CSV |
|
Connectivity |
USB-A |
2 ports for keyboard and/or printer or USB flash drive input |
USB-C |
1 port for PC connectivity and USB-C type flash drive |
|
Wi-Fi & Ethernet |
Log transfer and download (web server; e-mail; FTP) |
|
RS232 |
Connecting peripherals |
|
Calibration Reminder |
Daily |
0 minutes to 23 hours 59 minutes |
Periodic |
1 minute to 30 days, 23 hours and 59 minutes |
|
Disabled | ||
Users | Up to 9 users and the default administrator account | |
Power supply |
Adapter 100‑240 VAC or 24 VDC 2A | |
Terms of Use | 0 to 50 °C / 32 to 122 °F / 273 to 323 K, max 95% RH non-condensing | |
Dimensions / Weight | 205 x 160 x 77 mm / Approx. 1.2 kg |
pH/ORP/ISE Characteristics
Technical Specifications | Description | |
pH |
Range |
-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2,000 to 20,000 pH |
Resolution |
0.1 pH; 0.01 pH; 0.001 pH |
|
Accuracy |
±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) |
|
Temperature compensation |
Automatic or manual |
|
Calibration Points |
Up to 5 |
|
Calibration Type |
Automatic; Semi-automatic; Manual |
|
Standard Buffer |
Hanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 |
|
Custom Buffer |
Up to 5 |
|
Buffer Group |
Up to 5 |
|
1st calibration point |
Offset or Point (User Settings) |
|
Isopotential Point |
-2,000 to 20,000 pH |
|
mV |
Range |
-2000.0 mV to 2000.0 mV |
Resolution |
1mV; 0.1mV |
|
Accuracy |
±0.2 mV ±1 last significant digit |
|
Calibration |
Single point offset, ±2000.0 mV |
|
ISE |
Range |
1.0×10⁻⁵ at 300.0 ppt (g/L or mg/mL) |
Resolution |
1, 2, 3 significant digits |
|
Accuracy |
±0.5% (Monovalent Ions); ±1% (Divalent Ions) |
|
Calibration Points |
Up to 5 |
|
Calibration Type |
All standards/ Standards Groups |
|
Standard Buffer |
7 standard solutions available for each concentration unit |
|
Customized Buffer |
Up to 5 |
|
Buffer Group |
Up to 5 |
|
Temperature |
Range |
-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K |
Resolution |
0.1°C; 0.1°F; 0.1K | |
Accuracy |
±0.2°C; ±0.4°F; ±0.2K | |
Calibration |
Single Point or Adjustable |
Conductivity
Technical Specifications | Description | |
Conductivity |
Range |
0.000 to 9.999 μS/cm 1.000 to 9.999 mS/cm |
Resolution |
0.001 μS/cm |
|
Accuracy |
±1% of reading or ±0.010 μS/cm, whichever is greater |
|
Cell constant |
0.0500 to 200.0000 /cm |
|
Calibration Type |
Automatic or Manual |
|
Calibration Points |
Single; up to 5 |
|
Calibration Solutions |
84.00 μS/cm; 1.413 mS/cm; 5,000 mS/cm; 12.88 mS/cm; 80.00 mS/cm; 111.8 mS/cm |
|
Temperature Compensation |
Linear; Natural; Standard; Disabled |
|
Reference temperature |
5.0 to 30.0 °C (41.0 to 86.0 °F, 278.2 to 303.2 K) |
|
Temperature coefficient |
0.00 to 10.00 %/°C |
|
Resistivity |
Range |
1.0 to 99.9 Ω cm |
Resolution |
0.1 Ω cm |
|
Accuracy |
±1 % of reading or ±1 Ω cm, whichever is greater |
|
Total Dissolved Solids (TDS) |
Range |
0.000 to 9.999 ppm |
Resolution |
0.001 ppm |
|
Accuracy |
±1% of reading or ±0.01 ppm, whichever is greater |
|
Salinity |
Range |
0.00 to 42.00 PSU (Practical Salinity Units) |
Resolution |
0.01 PSU 0.01 ppt 0.1 % |
|
Accuracy |
±1% of reading |
|
Calibration |
1 point, using 100% salinity calibration solution (% scale only) |
|
Temperature |
Range |
-20.0 to 120.0 °C / -4.0 to 248.0 °F / 253.2 to 393.2 K |
Resolution |
0.1°C; 0.1°F; 0.1K |
|
Accuracy |
±0.2°C; ±0.4°F; ±0.2K |
|
Calibration |
Single or adjustable point |
Dissolved Oxygen
Technical Specifications | Description | |
Dissolved Oxygen |
Range |
0.0 to 500.0 % saturation |
Resolution |
0.1% saturation |
|
Accuracy |
Refer to the probe used |
|
Calibration Points |
1 or 2 points, at 100.0% (8.26 mg/L) and 0.0% (0.00 mg/L) |
|
Calibration Type |
Automatic |
|
Atmospheric Pressure |
Range |
450.0 to 850.0 mmHg |
Resolution |
0.1 mmHg |
|
Accuracy |
±3 mmHg within ±15% of calibration point |
|
Temperature Compensation |
Automatic (barometer integrated into the instrument) |
|
Temperature |
Range |
-20.0 to 120.0 °C |
Resolution |
0.1 °C |
|
Accuracy |
Refer to the probe used |
|
Compensation |
Automatic |
|
Calibration |
Single or adjustable point |
|
Salinity Compensation | Manual 0.00 to 45.00 PSU og/L (ppt) 0.0 to 130.0 % |
Fast Shipping | No |
---|